Product Information • Product Range • Features & Options
MCH Series frequency inverter: Features and Options

Standard Features

Enclosures:

NEMA 1

NEMA 4

NEMA 12

Control Terminals

Digital Inputs (Active low, NPN)

1 Dedicated Stop

4 Programmable

Digital Outputs:

2 Open Collector (NPN)

1 Form C Relay

Analog Inputs:

1 voltage (0-10VDC)

1 current (4-20mA)

Analog Outputs :

2 Outputs (0-10 VDC, 2-10 VDC can be converted to 4-20mA) proportional to speed and load

Serial Communications:

2-Wire RS-485 Modbus RTU protocol for programming, monitoring and controlling.
See below for more communication options.

Other:

Speed Potentiometer Power Supply

Signal Common

Programmable Features:

Carrier Freq. 2.5 - 14 kHz

Independent Accel and Decel Ramps

120 Hz Maximum Output Freq.(650 Hz available)

DC Injection Braking

PID Setpoint Control

Critical frequency avoidance bands

Speed References:

Keypad

Floating Point Control (MOP)

0-10 VDC Analog Reference (scalable)

4-20mA Analog Reference (scalable)

Potentiometer

4 Programmable Preset Speeds

Serial Communications Speed Reference

Standards and Conformance

UL & cUL (North America)

CE (Europe)

Low Voltage Directive (EN61800-5-1)

Two Year Warranty

Options:

Remote Keypad / Display

The remote keypad / Display provides for drive operation (start, stop, direction and speed), programming and monitoring. It provides all the functionality of the standard drive mounted keypad and display.

Dynamic Braking

Packaged Dynamic brake option includes control and resistors in an easy to implement solution for fast stopping or deceleration requirements

Communications:

The standard MCH Series drives all contain RS-485 Modbus RTU communications. Other popular HVAC communication protocols are optionally available in the MCH Series. The protocols include Johnson Controls Metasys N2, Siemens P1, BACNet and Echelon LONWorks

3-Contactor Bypass:

This option allows the motor to be operated “across-the-line” for critical applications where a redundant means of motor operation is required. This option is factory assembled and wired. The 3-contactor design allows the drive to be removed if required for service, while the bypass is left in place to operate the motor. The bypass can also be factory configured with door interlocked disconnect switch, door interlocked circuit breaker, line reactor, 24 VDC power supply and automatic transfer to bypass capabilities. The bypass option is available in NEMA 1 and NEMA 12 enclosures.

Option Box:

The option box allows options such as input disconnect switch, input fuses, and/or input line reactor to be added to the drive. These options are factory assembled and wired in a NEMA 1 enclosure.

 
Product Information • Product Range • Features & Options